The Miura LX-100 Boiler is being sold because its minimum capacity exceeds our current steam requirements.  
Boiler Specifications:
Boiler Output
Boiler Type	-	Multiple water tube, once through, forced flow, steam boiler
Maximum Allowable Working Pressure	PSIG	170
Recommended Operational Range	                PSIG	 70 - 150
Boiler Heating Surface Area	ft2            	        196
Boiler Horsepower Rating	                                BHP	100
Equivalent Output in	                                                lb/hr	3,450
Maximum Heat Output	                                        MMBTU/hr	3.348
Turn-Down	-	                                                        2:1 (50%)
Air and Fuel Requirements (Natural Gas/Propane)
Fuel Supply Pressure	                        PSIG	3-5 PSIG (Natural Gas or Propane)
Heat Input	                                        MMBTU/hr	3.939
Efficiencyii	                                        %	85%
Flue Gas Excess Oxygen	                %	5.0%
Flue Gas Temperatureii	                °F	270
NG/LPG Fuel Consumptioniii	SCFH / GPH	3,860 / 43.0
Required Air Volume	SCFH	        48,730
Flue Gas Volume - Wet	SCFH	52,590
Flue Gas Volume - Dryiv	SCFH	45,100
Flue Gas Velocity	ft/s	                19.8
Emissions (Natural Gas/Propane)
NOx Emission NG/LPGvii	        ppm (lbs/MMBTU)	100/130 (0.1217 / 0.1582)
CO Emission NG&LPGvii	                ppm (lbs/MMBTU)	100 (0.0739)
CO2 Emission NG/LPGvii	        lbs/MMBTU	117.6 / 136.6
VOC Emission NG&LPGvii	        lbs/MMBTU	0.0054
SO2 Emission NG/LPGviii	        lbs/MMBTU	0.00058 / 0.00055
Total PM Emission NG/LPGvii	lbs/MMBTU	0.0075 / 0.0077
Weights & Capacities
Boiler Shipping Weight	                lbs	4,600
Economizer Shipping Weight	lbs	700
Operational Weight	                        lbs	5,900
Operational Water Contentxi	Gal	65
Fully Flooded Water Contentxii	Gal   120
This boiler was purchased new by a distilling operation in Ontario Canada until 2015 when the operation ceased to exist.  The boiler was then sold to a used equipment broker until we purchased the unit in 2017.
If an interested buyer resides in the province of Ontario and is looking to utilize the unit in Ontario, we can offer an option to have the unit shipped, installed and  made operational.